Electrical Specification | |
Input Voltage/Output voltage | 100V /250V |
Input frequency | 47~63Hz |
Max. output power | 3.5KW (Single Phase) |
Max. output current | 16A |
Charging interface type | IEC 62196-2 |
Function and Accessory | |
Ethernet/WIFI/4G/Bluetooth | No |
LCD | 3.5-inch color display |
RCD | Type A / Type A+ 6mA DC |
LED Indicator light | Yes |
Intelligent power adjustment | Yes |
RFID | Opt |
APP | Opt |
Working Environment | |
Protection degree | IP 66 |
Environment temperature | -40ºC ~ +80ºC |
Relative humidity | 0-95% non-condensing |
Maximum altitude | <2000m |
Cooling | Natural air cooling |
Standby power consumption | <8W |
1. Product information | ||
Model | AJA02 | |
Standard | IEC61851-1 | |
Charging type | Mode3, Level 2 | |
2. Power Specifications | ||
AC input | 220~240V Max.32Asingle Phase | |
Input connection | L/N/PE | |
AC output | 7KW(230Vac@32A) | |
Energy Meter | MID classB | |
3. User interface | ||
Display | 3.5"LCD 800*480pixel | |
Status indication | LED | |
User authentication | RFID/QR code/APP | |
Communication | Ethernet/WIFI/4G/RS485 | |
Protocol | OCPP1.6J(Upgradeable to2.0)/Modbus TCP/WebSocket Secure/DLB | |
4. Mechanical | ||
Dimensions H×W×D | 352mm*155mm*130mm | |
Net Weight | 3.4KG | |
Charging interface | IEC62196-2(Type2) Cable3.5m | |
5. Enviromental | ||
Operating Temperature | -30ºC~+50ºC | |
Store Temperature | -40ºC~+80ºC | |
Humidity | ≤85% RH | |
Altitude | ≤2000m | |
Mounting | Wall or floor using a pedestal | |
IP and IK rating | IP55/IK10 | |
Enclosure | NEMA type3 | |
6. Protection | ||
RCD | A+dc6mA | |
Input line | Surge protection,OVP/UVP,ground fault protection | |
Output line | CP fault,MCU fault detection,OCP/OTP/,Residual current protection, PEN,Relay welding detection | |
7. Configuration | ||
Software update | OCPP1.6, web portal or App | |
Control and configuration | Web portal or App | |
8. Certification and standards | ||
Safety standards | IEC/EN 61851-1,IEC62955 | |
Certification | CE,MID |
1. Product information |
|
Model |
AJA01 |
Standard |
IEC61851-1 |
Charging type |
Mode3, Level 2 |
2. Power Specifications |
|
AC input |
380~415V Max.32Athree Phase 3P+N+PE |
Input connection |
L1/L2/L3/N/PE |
AC output |
22KW(@32A) |
Energy Meter |
MID classB |
3. User interface |
|
Display |
7"LCD 800*480pixel |
Status indication |
LED |
User authentication |
RFID/QR code/APP |
Communication |
Ethernet/WIFI/4G/RS485 |
Protocol |
OCPP1.6J(Upgradeable to2.0)/Modbus TCP/WebSocket Secure/DLB |
4. Mechanical |
|
Dimensions H×W×D |
410mm*295mm*137mm |
Net Weight |
9.6KG |
Charging interface |
IEC62196-2(Type2) case B connection(Socket) |
5. Enviromental |
|
Operating Temperature |
-30ºC~+50ºC |
Store Temperature |
-40ºC~+80ºC |
Humidity |
≤85% RH |
Altitude |
≤2000m |
Mounting |
Wall or floor using a pedestal |
IP and IK rating |
IP55/IK08 |
Enclosure |
NEMA type3 |
6. Protection |
|
RCD |
RCBO+dc6mA |
Input line |
Surge protection,OVP/UVP,ground fault protection |
Output line |
CP fault,MCU fault detection,OCP/OTP/,Residual current protection, PEN,Relay welding detection |
7. Configuration |
|
Software update |
OCPP1.6, web portal or App |
Control and configuration |
Web portal or App |
8. Certification and standards |
|
Safety standards |
IEC/EN 61851-1, IEC62955 |
Certification |
CE,MID |